Keypad
Press "M" key to display function code
Press "Up" or "Down" to select required function code
Press E to read data set in the function code
Press "Up" or "Down" to modify data
Press M to show corresponding target frequency by flashing after saving the set data
Press E to display the current function code

Set-Up Instructions

• Select the application mode. See Chapter 9 for the application description.
Press (M) until F100 is shown on the display
Press (O) until only the FWD LED is illuminated (X O X X)
Press (UP) to access parameter block F2xx
Press (O) until both the FWD and DGT LEDs are illuminated (X O O X)
Press (UP) until display shows F228
Press (E) to edit the application number
Use the (UP) and (DOWN) keys to select the application
Press (E) to confirm your selection
• Set the Motor Paramaters
• Select control mode
The AC10 inverter has three control modes: sensorless vector control (F106=0), VVVF control (F106=2) and vector control 1 (F106=3). Under VVVF control
mode, theAC10 inverter has four kinds of torque compensation modes: Linear compensation (F137=0); Square compensation (F137=1); User-defined
multipoint compensation (F137=2); Auto torque compensation (F137=3)
• Set the limits
F119 The reference of setting accel/decel time
When F119=0, acceleration/ deceleration time means the time for inverter to accelerate/ decelerate from 0Hz (50Hz) to 50Hz (0Hz).
When F119=1, acceleration/ deceleration time
Application selection
F228
F801 Rated power (kW)
F802 Rated voltage (V)
F803 Rated current (A)
F804 Number of motor poles
F805 Rated rotary speed (rmp/min)
F810 Motor rated frequency (Hz)
F111 Max Frequency (Hz)
F112 Min Frequency (Hz)
F114 First Acceleration Time (S)
F115 First Deceleration Time (S)
F116 Second Acceleration Time (S)
F117 Second Deceleration Time (S)
www.comoso.com
LED shows running frequency, flashing target frequency,
function code, parameter value or fault code.
4 LEDs indicate working status. RUN while running. FWD running
forward and FRQ when the MMI is showing frequency.
Press "M" for function code, and "E" for
original parameters.▲and▼keys can be used to select
function codes and parameters. Press "E" again to
confirm. In the mode of keypad control, ▲and▼keys can
also be used for dynamic speed control. "I" and "O" keys
control start and stop. Press "O" key to reset inverter in
fault status.
0: Invalid
1: Basic speed control
2: auto/manual control
3: Stage speed control
4: Terminal control;
5: PID control;
Setting range: 0.75~1000
Setting range: 1~460
Setting range: 0.1~6500
Setting range: 2~100
Setting range: 1~30000
Setting range: 1.0~650.0
Setting range: F113~650.0
Setting range: 0.00~F113
Setting range:
Mfr's value: subject to inverter model
0.1~3000
Setting range: 0: 0~50.00Hz
1: 0~F111
4
50.00
Mfr's value: 50.00
Mfr's value: 0.50
Mfr's value: 0
1-6