Type 2030, 2031, 2031 K, 2032,
2033, 2037
Technical Data
6.8 application conditions
Warning!
danger of bursting from overpressure.
If the device explodes, there is a risk of serious injuries, chemical
burns, scalding!
▶ Do not exceed the maximum control and medium pressure.
Observe specifications on the type label!
▶ Observe permitted ambient and media temperature.
ambient temperature for actuators:
material
size ø
PA
40 - 125 mm
40 - 80 mm
PPS
100 mm, 125 mm
medium temperature for body:
body material
Stainless steel
PVC (see PT graph)
PVDF (see PT graph)
PP (see PT graph)
medium temperature for diaphragms:
material
temperature
EPDM / PTFE
-10 ... +130 °C
FKM
-5 ... +130 °C
All manuals and user guides at all-guides.com
temperature
-10 ... +60 °C
+5 ... +140 °C
+5 ... +90 °C (briefly up to +140 °C)
temperature
-10 ... +140 °C
-10 ... +60 °C
-10 ... +120 °C
-10 ... +80 °C
comments
Steam sterilization up to +150 °C
Dry up to +150 °C
otherwise only briefly up to +150 °C
maximum permitted medium pressure:
Permitted medium pressure depending on the medium temperature
for plastic bodies:
DN 15 - 65
10
8
6
4
2
Temperature [°C]:
Fig. 1:
Graph of medium pressure / medium temperature
permitted control pressure*:
actuator size
actuator
ø [mm]
material
40 - 100
PA
125
PA
40 - 125
PPS
Observe the permitted pressure range according to the
*
type label!
english
PVDF
PP
PVC
20 40 60 80 100 120 140
min. control
max. control
pressure [bar]
pressure [bar]
2
10
2
7
2
7
7