Burkert 2030 Guide Rapide page 11

Masquer les pouces Voir aussi pour 2030:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type 2030, 2031, 2031 K, 2032,
2033, 2037
7.3 installation
If used in a corrosive environment, we recommend running
a pneumatic hose from all free pneumatic connections to a
neutral atmosphere.
Warning!
risk of injury from incorrect installation.
Non-observance of the specified tightening torque is hazardous
as the device may be damaged.
▶ Observe tightening torque during installation (see "Tab. 2: Tight-
ening torques for diaphragms").
7.3.1
devices with welded or bonded body
note!
to avoid damage!
Before welding or bonding the body, the actuator and dia-
phragm must be removed.
remove actuator and diaphragm from the body:
procedure for control function a
Pressurize the lower control air connection with compressed air
(value on type label) (see "Fig. 7: Control air connection"). This
is required so that the diaphragm detaches from the body and is
not damaged.
Loosen fastening screws in diagonal pairs and remove actuator
together with diaphragm from the body.
Weld or glue body into the pipeline.
procedure for control functions b and i
Loosen fastening screws in diagonal pairs and remove actuator
together with diaphragm from the body.
Weld or glue body into the pipeline.
All manuals and user guides at all-guides.com
Assembly
mount actuator and diaphragm on the body:
After welding or bonding the body, smooth the body surface by
grinding if required.
Carefully clean the body.
procedure for control function a
Pressurize the lower control air connection with compressed air
(value on type label) (see "Fig. 7: Control air connection").
Place actuator on the body.
Gently tighten the body screws in diagonal pairs until the dia-
phragm lies between the body and actuator.
do not fully tighten screws yet.
Actuate the diaphragm valve twice to position the diaphragm
correctly.
Without applying pressure, tighten the body screws to the permitted
tightening torque (see "Tab. 2: Tightening torques for diaphragms").
Pressurize the lower control air connection with compressed air
(value on type label).
Check the tightening torque of the screws again.
procedure for actuator with control functions b and i:
Place actuator on the body.
Gently tighten the body screws in diagonal pairs without pres-
surization until the diaphragm is between the body and actuator.
do not fully tighten screws yet.
Pressurize the lower control air connection with compressed air
(value on type label) (see following "Fig. 7: Control air connection").
Actuate the diaphragm valve twice.
Tighten the body screws to the permitted tightening torque
(see "Tab. 2: Tightening torques for diaphragms").
english
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

20312031 k203220332037

Table des Matières