4.2 Application conditions
Ambient temperature:
max. +55 °C
Permitted medium temperature depending on coil material and sealing
material:
Circuit
Coil
Frequency
function
material
Polyamide
(AC10)
Control
function A
AC/DC/UC
(NC)
AC
Epoxide
Control
function B
(NO)
DC/UC
CF A (NC) /
AC/DC/UC
CF B (NO)
Sealing
Medium
material
temperature
FKM (FF)
-10...+100 °C
FKM (FF)
-10...+140 °C
EPDM (AA)
-30...+120 °C
NBR (BB)
-10...+80 °C
PTFE + PEEK (EP) -40...+180 °C
FKM (FF)
-10...+100 °C
EPDM (AA)
-30...+100 °C
PTFE + PEEK (EP) -40...+100 °C
PTFE + FKM (EF)
-10...+140 °C
PTFE + PEEK (EP) -40...+180 °C
EPDM (AA)
-30...+120 °C
FKM (FF)
-10...+140 °C
PEEK + FKM (TF)
-10...+80 °C
Permitted medium temperature and ambient temperature depending on
sealing material:
Temperatures for valves with UL/UR approval
Sealing material
EPDM (AA)
PTFE + EPDM (EA)
Ambient temperature
PTFE + FKM (EF)
PTFE + PEEK (EP)
FKM (FF)
EPDM (AA)
PTFE + EPDM (EA)
Medium temperature
PTFE + FKM (EF)
PTFE + PEEK (EP)
FKM (FF)
Operating duration:
Unless otherwise indicated on the type label,
the solenoid system is suitable for continuous
operation
english
-10...+55 °C
-30...+120 °C
-10...+140 °C
-40...+140 °C
-10...+140 °C
5