Vibration EN 60745
Weight w/o cable
Protection class
The specified vibration value was measured with a
standardised test procedure. It can be used to
compare products or to make an initial assess-
ment of the exposure. The vibration emissions may differ
from the specified value, depending on how the power
tool is used. Operating personnel must be protected with
defined safety measures based on the estimated expo-
sure under the actual conditions of use (these must take
into account all phases of the operating cycle, e.g. the
times when the power tool is switched OFF and the times
it is switched ON, but is not under load).
2.4 o
perAting conditions
Temperature range during operation: 0 to +50°C
Relative air humidity: 95 % at +10°C not condensed
3.
handlIng
3.1 p
rotectiVe deVises
The machine may only be operated with
the safety guards and the additional han-
dle fitted!
3.1.1 s
Afety guArd
f
it protectiVe guArd
The bolts and the grooves must align.
6.9m/s
, K=1.5m/s
A
2
2
djustment of sAfety guArd
1.9kg
II
Bring the safety guard into the desired working position.
For fastening the screw must be tightened down. To re-
lease, turn screw back approx. ½ rotation. Safe operation
is guaranteed only with tightened screw. If the cowl can
no longer be turned with ease, the locking mechanism
must be cleaned.
r
emoVAl of sAfety guArd
If necessary, release screw with Allen key. Bring bolt and
/ o
peratIon
groove into alignment and remove the safety guard.
c
leAning of locKing mechAnism
Remove safety guard as mentioned above.
Remove clamping nut and backing flange.
Loosen and remove the three clamping screws.
25