2.3 r
Ating dAtA
Voltage
3~400-480V, 50-60Hz, 9.5-7.9A
Power Input
Power Output
Protection class
Type of protection
Overload protection
No-load speed
Sound pressure level
Threaded connection for flexible shafts of type:
DIN 15
NA 10, NA 12, NA 15
NA 12 DIN 15/G28 STEP
NA 15 DIN 15/G35 STEP
2.3.2 V
iBrAtion mesurement VAlues of hAnd tools
FH 15
Measurement value 3.1m/s
SAM 1:1
Measurement value 6.6m/s
BSG 10
Measurement value <2.5m/s
FSM 1:1
Measurement value 4.7m/s
WI 10
Measurement value 3.5m/s
WH 15
Measurement value <2.5m/s
WH 12
Measurement value <2.5m/s
FH 12
Measurement value 7.1m/s
BSG 15
Measurement value <2.5m/s
According to ISO/EN 60745.
The specified vibration value was measured with a
standardised test method and may differ from the
actual operating value. The specified value can be
used for product comparisons or for an introductory as-
sessment of work breaks.
2.4 o
perAting conditions
Temperature range during operation: 0 to +50°C
Relative air humidity: 90% at +30°C, 65% at +50°C
To avoid strong looping movements and beaming
of the flexible shafts, the working pressure must
be reduced.
4000W
3.1 m
3500W
1
IP45
3.1.1 c
yes
500-10000min
-1
75dB(A), K=1.5m/s
2
M14
see catalog
see catalog
see catalog
/K=1.5m/s
2
2
Drive 10000min
Speed gauge (1). Speed correction «-/+» (2). Speed con-
-1
/K=1.5m/s
firmation «enter» (3). «run» start command (4). «stop» stop
2
2
Drive 6400min
command (5). ON/OFF «step» safety device (6).
-1
/K=1.5m/s
2
2
Drive 7000min
3.1.2 s
-1
/K=1.5m/s
2
2
Drive 7000min
-1
/K=1.5m/s
2
2
Drive 15000min
During operation make sure that the flexible shafts have
-1
/K=1.5m/s
large bend radius.
2
2
Drive 5000min
Before starting the machine, hold the hand tool against
-1
/K=1.5m/s
turning!
2
2
Drive 10000min
Operate power switch of the machine.
-1
/K=1.5m/s
Speed gauge blinking.
2
2
Drive 12000min
Pre-select speed with key «-/+».
-1
/K=1.5m/s
The speed gauge blinks until the pre-selection is con-
2
2
Drive 5000min
firmed with the «enter» key.
-1
The speed is saved.
If a start command is not issued within 60 seconds, the
speed gauge will start to blink.
Now pre-select the speed again by pressing the «enter»
key.
Press the «run» key = Start the machine.
During operation the speed can be varied with the «-/+»
keys.
3.1.3 m
Press «stop» key.
Hold hand tool steady until the speed Zero is reached.
Speed blinks.
3. h
andlIng
Achine
ontrol KeypAd
tArting the mAchine
Before turning on the machine, make sure to re-
move wrenches and adjusting tools.
When turning on, hold the flexible shaft extended.
Achine stop
/o
PeratIon
33