ABICOOLER 1300 115V CSA
Tab. 3
Faults and troubleshooting
Fault
Leakage
11 Disassembly
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
NOTICE
► Only qualified personnel are permitted to perform work on the device or system.
► Please also consult the operating instructions for the welding components and welding torch.
► Observe the information provided in the following section:
Disconnect from the power supply.
1
Disconnect all supply connections.
2
12 Disposal
Dispose of BTC coolant
The coolant must not be disposed of with normal household waste. Do not allow the product to enter the
sewage system.
► Please take note of the following information in the safety data sheet:
— 14 06 03*: Other solvent and solvent mixtures
— 15 01 10*: Packaging containing residues of or contaminated by dangerous substances.
— 15 01 02: Plastic packaging.
Contaminated packaging: Disposal in accordance with official regulations.
Cause
The connections have leaks.
Inner hoses have leaks.
Coolant pump is defective.
Coolant temperature is too high.
WARNING
CAUTION
8 Decommissioning on page EN-16.
Equipment marked with this symbol is covered by European Directive 2012/19/EU on
waste electrical and electronic equipment (WEEE).
► Do not dispose of electrical and electronic equipment with household waste.
► Disassemble electrical equipment prior to proper disposal.
11 Disassembly on page EN-21
► Collect components of electrical separately and recycle in an environmentally
responsible manner.
► Observe local regulations, laws, provisions, standards and guidelines.
► Please consult your local authority for information about collection and return of
electrical devices.
11 Disassembly
Troubleshooting
► Check for dirt and clean as needed.
► Contact the service team.
► Contact the service team.
► Replace the hoses.
► Contact the service team.
► Clean the cooling unit.
► Check the fan for proper function.
EN - 21