FES-200 W3
11 Disassembly
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Disconnect the mains plug.
• Always wear your personal protective equipment when dismounting the system.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask
• Nobody without personal protective equipment may stay near the fume extraction system when it is
• It is not allowed to clean the fume extraction system using compressed air or a hammer.
NOTICE
• Disassembly must only be carried out by qualified personnel (in Germany, see TRBS 1203).
Fig. 2 Functional description on page EN-12
1 Remove the knurled nuts (9) from the dust collecting drawer (8).
2 Carefully pull out the dust collecting drawer (8).
3 Slide the full dust collecting drawer (8) into the dust collecting bag supplied.
4 Close the dust collecting bag tightly.
5 Unscrew the mounting screws (3) from the cover and lift it off.
6 Place the cover on the fume extraction system.
7 Place the dust collecting bag completely over the filter cartridge.
8 Loosen the filter cartridge (5) by turning it to the left (counter-clockwise direction).
9 Remove the filter cartridge (5) and slide it completely into the dust collecting bag.
10Close the dust collecting bag tightly.
11 Package the fume extraction system in an appropriate way. In doing so, observe the local regulations.
12 Dispose of the dust collecting bag and the fume extraction system according to the local regulations.
12 Disposal on page EN-26
DANGER
CAUTION
Class P3, protective gloves and safety shoes.
being disassembled.
11 Disassembly
EN - 25