11 Disassembly

DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Disconnect all electrical connections.
CAUTION
• Check and wear your personal protective equipment.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask Class P3, protective
gloves and safety shoes.
• Nobody without personal protective equipment may stay near the fume extraction system when it is being
disassembled.
• It is not allowed to clean the fume extraction system using compressed air or a hammer.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
 Fig. 2 Functional description on page EN-11
1 Remove the knurled nuts (9) from the dust collecting drawer (8).
2 Carefully pull out the dust collecting drawer (8).
3 Slide the full dust collecting drawer (8) into the dust collecting bag supplied.
4 Close the dust collecting bag tightly.
5 Unscrew the mounting screws (3) from the cover and lift it off.
6 Place the cover on the fume extraction system.
7 Place the dust collecting bag completely over the filter cartridge.
8 Loosen the filter cartridge (5) by turning it to the left (counter-clockwise direction).
9 Remove the filter cartridge (5) and slide it completely into the dust collecting bag.
10Close the dust collecting bag tightly.
11 Package the fume extraction system in an appropriate way. In doing so, observe the local regulations.
12 Dispose of the dust collecting bag and the fume extraction system according to the local regulations.
 12 Disposal on page EN-24