7 Operation

7 Operation
Risk of injury from hot coolant
If the coolant tank is opened during or immediately after operation, coolant may spray out and cause
burns or irritation to skin and mucous membranes.
► Keep the coolant tank closed during operation.
► Wait at least 5 seconds after switching off before opening the screw cap of the coolant tank.
► Check and wear your personal protective equipment.
► Switch the device on and off with the ON/OFF switch.

7.1 Prior to initial commissioning and after a longer standstill

Bleed the device and cable assembly.
1
 6.2.2 Bleeding the device on page EN-13
 6.2.3 Bleeding the cable assembly on page EN-14
Check the tightness of the coolant connections.
2

8 Decommissioning

► Observe the documentation for the welding components.

9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
Electric shock due to missing grounding
If the housing of the device is improperly mounted, the grounding may not be properly established.
There is a risk of life-threatening electric shock.
► The housing may be disassembled and assembled only by a qualified electrician for maintenance
► Each time the cover plates are opened, have a safety inspection performed in accordance with
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
► Leave the device switched off throughout the entire bleeding process.
EN - 16
WARNING
WARNING
and cleaning work.
DIN IEC 60974 Part 4: "Regular inspection and testing" by ABICOR BINZEL or another authorized
specialist.
WARNING
CAUTION
ABICOOLER 1300 115V CSA
Switch off the device.
1
Pull out the mains plug to disconnect from the
2
power supply.