FUSE CHECK/REPLACEMENT
1.
Remove the recovery tank as shown in the Use chapter.
2.
Disconnect the battery negative terminals (50).
3.
Remove the screws (A, Fig. 10), then carefully remove the electrical component box cover (B).
4.
Check/replace the fuses:
•
Brush (40 A) (C)
•
Vacuum system (40 A) (D)
•
Solenoid valve and electronic board (5 A) (E)
5.
Assemble in the reverse order of disassembly.
A
B
A
Figure 10
Micromatic™ M17B
INSTRUCTIONS FOR USE
E
D
C
909 5853 000(4)2009-11
ENGLISH
S310234A
21