ENGLISH
USE
WARNING!
On some points of the machine there are some adhesive plates indicating:
–
DANGER
–
WARNING
–
CAUTION
–
CONSULTATION
While reading this Manual, the operator must pay particular attention to the symbols shown on the plates.
Do not cover these plates for any reason, in case of damage replace them immediately.
BATTERY CHECK/SETTING ON A NEW MACHINE
WARNING!
The electric components of the machine can be seriously damaged if the batteries are either improperly installed
or connected. The batteries must be installed by qualifi ed personnel only. Check the batteries for damage before
installation. Handle the batteries with great care. Install the battery terminal caps supplied with the machine.
The machine requires two 12V batteries, connected according to the diagram (51).
The machine can be supplied in one of the following modes:
GEL batteries already installed on the machine
–
Start the machine by pressing the brush/pad-holder and vacuum system switches (65 and 66). If the green warning light (62)
turns on, the batteries are ready to be used.
–
If the yellow or red warning light (63 or 64) turns on, it is necessary to charge the batteries before using the machine (see
procedure in Maintenance chapter).
Without batteries
–
Buy appropriate batteries [See the Technical Data paragraph and the diagram (51)]. For the battery choice and installation,
apply to qualifi ed battery retailers.
–
Set the machine for GEL batteries, then install the batteries on the machine and charge them, as shown in the next paragraph.
GEL BATTERY SETTING, INSTALLATION AND
CHARGING
The electronic board of the machine is to be set according to
the type of batteries chosen, gel (GEL) batteries. Proceed as
follows.
Machine setting
1.
The machine factory setting is for GEL batteries; if this
setting corresponds to the type of batteries supplied, go to
step 4. Otherwise, carry out steps 2, and 3 too.
2.
Remove the screws (A, Fig. 1), then remove the electrical
component box cover (B).
WARNING!
Do not move/set the adjacent switch (D).
3.
Reinstall the electric component box cover (B) and tighten
the screws (A).
10
INSTRUCTIONS FOR USE
909 5853 000(4)2009-11
D
C
A
B
A
Micromatic™ M17B
Figure 1
S310234B