1.1.2.
IND231/IND236 Terminal Types
The terminal is available in the following four versions:
•
•
•
•
1.2.
Use in Hazardous Areas
The IND231/236 terminal does not have any hazardous area approvals for use directly in explosive
environments; however, it is capable of operation with load cells and platforms in a Division 1/2 or
Zone 0/1/2/21/22 hazardous area when used with approved barriers or when purging is utilized.
Contact your authorized METTLER TOLEDO representative for information about hazardous area
applications for the IND231/236 terminal.
1.3.
Specifications
The IND231 and IND236 terminal conforms to the specifications listed in Table 1-1.
Enclosure Type
Product Dimensions
(w × h × d)
Shipping Dimensions
(w × h × d)
Product Weight
Shipping Weight
1-2
METTLER TOLEDO IND231/IND236 Guía de instalación
Automatic shutoff and backlight timeout features to help conserve energy and extend battery
life when using the battery powered version
IND231plastic housing, AC power (also designed for use with AA size alkaline cells)
IND231plastic housing, Rechargeable Ni-MH Battery power
IND236 stainless steel housing, AC power
IND236 stainless steel, Rechargeable Ni-MH battery power
THE IND231/236 TERMINAL DOES NOT HAVE ANY HAZARDOUS AREA APPROVALS! DO NOT
USE WITHIN AREAS CLASSIFIED AS HAZARDOUS DIVISION 1/2 OR ZONE 0/1/2/21/22
BECAUSE OF COMBUSTIBLE OR EXPLOSIVE ATMOSPHERES.
Specifications
Plastic, configurable as desk top or
column/wall mount enclosure
220 mm x 150 mm x 102 mm
(8.66 in. x 5.90 in. x 4.02 in.)
AC Version: 1.2 kg (2.6 lb)
Battery Version: 1.5 kg (3.3lb)
2.0 kg
WARNING
Table 1-1: Terminal Specifications
IND231
350 mm x 220 mm x 195 mm
(13.78 in. x 8.66 in. x 7.68 in.)
IND236
Stainless steel, configurable as desk
top or column/wall mount enclosure
220 mm x 150 mm x 93.3 mm
(8.66 in. x 5.90 in. x 3.67 in.)
AC Version: 2.2 kg (4.9 lb)
Battery Version: 2.5 kg (5.5 lb)
3.0 kg
30094756
|
04
|