2. Position the battery in the enclosure and install the bracket provided using two screws, as
3. Attach the battery cable to the connector indicated in Figure 2-20.
4. Replace the plastic cover, pressing it sideways so that it snaps into place.
2.4.5.2.
IND236
To install and connect the NiMH battery pack in the IND236 terminal:
1. Open the enclosure – refer to section 2.1, above.
2. Position the battery in the enclosure and secure it in place using the bracket provided and two
3. Attach the battery cable to the connector on the charging board, indicated in Figure 2-22.
4. Close the enclosure – refer to section 2.6, below.
30094756
|
04
|
02/2021
shown in Figure 2-21.
Figure 2-21: NiMH Battery Installed in IND231
hexagonal stand-offs, as shown in Figure 2-22.
Figure 2-22: NiMH Battery Installed in the IND236
METTLER TOLEDO IND231/IND236 Installation Manual
2-11