Molift Air / www.etac.com
Electronics
Transport and Storage
For long time storage it is recommended that the emergency
stop button is activated (pulled out). The lifter can be stored and
transported under temperatures between -25 - 70 °C.
Operating
The lifter is designed for use at standard room temperatures (+5
to +40°C).
Air Pressure: 70 - 106 kPa
Relative Humidity: 15 - 93 %
Following storage or transport at other temperatures leave the
lifter in a room with a suitable temperature until it reaches a safe
operating temperature.
Medical electrical equipment requires special
precautions regarding electromagnetic
compatibility (EMC). Portable or mobile radio
communication equipment may affect the
medical electrical equipment, and should
be kept minimum 25 cm (10 inches) from the
lifters electronics.
Batteries
Molift Air 200/350 is available with 2 x 12V SLA battery or a
25.6V LiFePO4 battery.
The SLA battery has a life expectancy of approx. 500 charge
cycles.
The LiFePO4 battery has a life expectancy of approx. 2000 charge
cycles.
Batteries must be disposed of as special
waste according to local rules and regula-
tions. Do not dispose in general waste
Battery and service indicator on lifter
Wrench symbol /
Service indicator
Battery symbol /
Battery indicator
The electrical system has a power-save function
which will turn off the electrical system five
minutes after last operation. All indicators will turn off.
The system is activated when pushing one of the operating but-
tons on the hand control.
Battery indicator on hoist
When the multi level battery indicator is yellow the lifter will
have sufficient power available for at least one full lifting cycle
with max load. When battery is flashing yellow it is only possible
to lower the sling bar.
Battery indicator
Green
Green
Green
Green
Yellow
Yellow
flashing
Service indicator / Periodic inspection
The lifters electronics record the weight lifted and number of
lifts. After a certain period of operation a signal is given to
indicate that service is required.
Service indicator
No light
Yellow
Green flashing
Red
Service scope
Service involves replacing the lifting belt and inspection/
replacement of worn parts. This must be carried out by author-
ized personnel. Service is needed when the service light is red
(calculated 5.000 lifts in weight class 2). Contact Etac your local
dealer, or see etac.com for a recommendation of an approved
service partner.
Charging
Molift Air can be charged through the hand control with a bat-
tery charger, or through the rail with In Rail Charging.
Hand control charging
The battery charger is plugged into a power outlet. Wall-mounted
docking for hand control is available. Make shure not to damage
the cable. The charger can be connected to the power outlet
at all times. Use only Molift chargers. The Hand control has an
indicator light that will illuminate when battery level is low and
the lifter requires charging.
Charger for Molift Air hand control: Art. no.: 2540100
Battery indicator
Hand Control
Wall Mounted Docking
Charging cable
5
Battery level
80% or more
80 - 60%
60 - 40%
40 - 20%
20% - 0%
0%
Mode
No service needed
Periodic inspection
required
Order service
Perform service