Sun Microsystems StorEdge T3 Manuel D'installation, D'utilisation Et De Service page 50

Masquer les pouces Voir aussi pour StorEdge T3:
Table des Matières

Publicité

4. Tapez fru list pour afficher les versions des microprogrammes des disques,
des unités disque et de la carte d'interconnexion sur les deux modèles de baie.
Par exemple (configuration enterprise) :
:/:<6>fru list
ID
TYPE
------
-----------------
u1ctr
controller card
u2ctr
controller card
u1d1
disk drive
u1d2
disk drive
u1d3
disk drive
u1d4
disk drive
u1d5
disk drive
u1d6
disk drive
u1d7
disk drive
u1d8
disk drive
u1d9
disk drive
u2d1
disk drive
u2d2
disk drive
u2d3
disk drive
u2d4
disk drive
u2d5
disk drive
u2d6
disk drive
u2d7
disk drive
u2d8
disk drive
u2d9
disk drive
u1l1
loop card
u1l2
loop card
u2l1
loop card
u2l2
loop card
u1pcu1
power/cooling unit TECTROL-CAN
u1pcu2
power/cooling unit TECTROL-CAN
u2pcu1
power/cooling unit TECTROL-CAN
u2pcu2
power/cooling unit TECTROL-CAN
u1mpn
mid plane
u2mpn
mid plane
Dans cet exemple,
La version du microprogramme des unités disque est indiquée comme
Revision
La version du microprogramme de la carte d'interconnexion (loop card) est
indiquée comme Revision 5.03 Flash.
La version du microprogramme EPROM du contrôleur Sun StorEdge T3 est
indiquée comme Revision 0200.
Le microprogramme du contrôleur de niveau 2 Sun StorEdge T3+, l'image de
niveau 2 est 0200.
2-22
Manuel d'installation, d'utilisation et de service des baies de disques Sun StorEdge T3 et T3+ • octobre 2001
VENDOR
MODEL
-----------
-----------
0034
501-5710-02( 0200
0034
501-5710-02( 0200
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN 9329
SEAGATE
ST118202FSUN EA29
SCI-SJ
375-0085-01-
SCI-SJ
375-0085-01-
SCI-SJ
375-0085-01-
SCI-SJ
375-0085-01-
300-1454-01( 0000
300-1454-01( 0000
300-1454-01( 0000
300-1454-01( 0000
SCI-SJ
375-0084-01- 0000
SCI-SJ
375-0084-01- 0000
9329.
REVISION
SERIAL
-------------
--------
123456
123455
LK478728
LK493799
LK493800
LK494457
NK040486
LK339351
LK150715
NK040157
LKG79907
LKG90019
LKH18597
LKH15606
LKH16563
LKG88883
LKH61907
LKG90719
LKG95442
LKG61774
5.03 Flash
007924
5.02 Flash
007382
5.02 Flash
003343
5.02 Flash
003344
001455
001408
001686
001445
000650
000649

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Storedge t3+

Table des Matières