Télécharger Imprimer la page

IPC Gansow Ct100 Manuel D'instructions page 49

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 68
5.4.2 Batteries: installation and connection
Check that the emergency button on the control panel is at the position "0" (off).
Mind you connect only the clips marked with the symbol "+" to the positive poles.
Do not check the battery charge by creating sparkles.
Stick scrupulously to the instructions described below, as any short circuits of the
1) Stop the machine and press the emergency button (fig. 8, ref. 2); engage the parking
brake by means of the pedal (fig. 8, ref. 12);
2) make sure that the two tanks are empty (empty them, if necessary: see respective
paragraph);
3) unhook the recovery tank (fig. 2, ref. 2) from the solution tank (fig. 2, ref. 3) acting on
the blocking hook (fig. 7, ref. 1), placed on front of the machine;
4) lift the recovery tank, by making it turn backwards around about 90° : in this way you
have access to the battery compartment (embedded in the solution tank) from the
upper side;
ensure that the recovery tank is empty (an acoustic warning device will sound if
you try to open the recovery tank without emptying it first);
ensure that the emergency button is pressed.
5) insert the batteries in the compartment, orienting them as shown in the drawing printed
on the solution tank in the compartment.
Install the storage batteries on the machine using suitable means according to
Positive and negative poles have different diameters.
6) Referring to the arrangement of cables in the aforesaid drawing, connect the clips of
the battery wiring and the bridge to the poles of the storage batteries. After orienting
the cables as shown in the drawing, tighten the clips at the poles and cover them with
vaseline;
7) insert back the tank unit in its work position and hook it to the solution tank by means
of the fixing hook (fig. 7, ref. 1);
8) use the machine in compliance with the instructions written below.
5.4.3 Batteries: removal
When removing the batteries, the operator must be equipped with suitable personal
protection devices (gloves, goggles, overalls, safety shoes, etc) to reduce the risk
of accidents. Make sure the switches on the control panel are in the "0" position
(off) and the machine is turned off. Keep away from naked flames, do not short
circuit the battery poles, do not cause sparks and do not smoke. Proceed as
follows:
• disconnect the battery wiring and bridge terminals from the battery poles.
• if necessary, remove the devices fixing the battery to the base of the machine.
• lift the batteries from the compartment using suitable lifting equipment.
! DANGER
batteries may cause them to explode.
WARNING
Before opening the upper tank:
WARNING
their weight.
! DANGER
ENGLISH
11

Publicité

loading

Ce manuel est également adapté pour:

Jet 100Lavamatic 680Lavamatic 810