•Act No. EN 06 1008 fire protection of local device and sources of heat
•Act No. EN 33 2000 environment for electric devices
It must first determine if the appliance is made for the same type of gas that will be used and thus conforms
to the indications on the label the type of gas to be used.
The conversion of gas pan to another type of gas you need to check if it corresponds to the type of gas
bearing, which is recommended in this guide.
Connecting the appliance to the gas distribution must be towable to a steel or copper tube complying with
applicable national requirements. This must be controlled on regular basis and changed if needed. Every
appliance must be equipped with shut-off valve and quick shut-off valve. Quick shut-off valve must be freely
accessible and within reach of the device. After installation, is necessary to check whether there is a gas
leak. To find a gas leak you can use soapy water or spray for gas leak detection.
Do not use corrosive substances!! All our appliances are carefully controlled. Gas type, pressure and of
the categories listed named on the technical information plate.
Liquid gas connection:
Pressure for liquid gas connection must be 28 or 30 mbar for propane/butane and 37 mbar for propane. It is
necessary to check the technical label ,gauge the pressure and check the parameters of the nozzle is
installed with the required parameters of the nozzle according to the manufacturer's. If the pressure is lower
than 25mbar or higher than 37 mbar, THE APPLIANCE SHALL NOT TO BE CONNECTED.
Gas Connection:
Pressure for methane connection must be 18 or 20 mbar. It is necessary to check the technical label
,gauge the pressure and check the parameters of the nozzle is installed with the required parameters of the
nozzle according to the manufacturer's. If the gas pressure is lower than 15mbar or higher than 22,5 mbar,
THE APPLIANCE SHALL NOT TO BE CONNECTED.
Water connection is performed with hose threaded G1/2. Connection to the water can be made after
removing front panel (Fig.1). The water supply must be equipped with a separate valve which is freely
available and within range of the device. The equipment includes a check valve.
• Water hardness must be in range 0,5 - 5 ° French degree. If higher, it is necessary use water softening
system.
• Water pressure must be within range 50 - 250kPa.
• Volume of chlorine in the water shall not be higher than 10ppm, or you risk bath surface damage
• Acidity of water must be higher than 7 pH.
• Electrical conductivity: 50 - 2000uS/cm (20°C)
• The connection must be made according to directive EN 1717 and with valid to national directives for
aquaculture.
Measures for the rebuilding and installing a different type of gas
Our appliances are certified and regulated the natural gas (see technical plate). Conversion or adaptation
to a different type of gas must be performed by authorized personnel. Nozzles for different types of gas are
in a bag provided with the pan and are marked in hundredths of mm (table of technical data pipes).
Nozzle replacement:
Connect gas hose connection
Water connection