Output Current
Iout = 0A
0.5V ( for 12V input )
1.0V ( for 24V input )
1.5V ( for 36V input )
2.0V ( for 48V input )
3.3.8
Programming field 7 : output current limitation
3.3.9
Programming field 8 : select thermal probe for alternator
This function enables to protect the alternator from excessively high temperatures. Over a programmable
temperature threshold, the output current decreases.
Input start-up
Setting
Output current limitation
1
2
3
4
5
6
7
8
9
10
Setting
Maximum external probe temperature
0
1
2
3
4
5
Iout = Nominal current
voltage
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Disable
70°C
80°C
90°C
100°C
110°C
Input Voltage
40