12
13
14
15
Some specific settings are possible – please consult us.
(*) Voltage on + BAT with 10% of the rated current and a tolerance of +/- 1%.
(
)
**
REFRESH is not advised for certain types of AGM batteries
(***) Battery Management System
3.3.3
Programming field 2 : Select special mode
-
The BOOST function allows a faster charging of the batteries. This function is timed in time (see section 3.3.2.)
And is automatically inhibited if the battery is charged: shutdown of the BOOST for a battery current <20% of the
nominal current of the charger / converter (2A in the case of the Lithium curve Iron Phosphate with BMS with a
minimum time of 10 minutes).
-
The REFRESH function allows to apply a voltage step periodically to maintain the battery, to promote its
equalization and thus prevent possible sulfating.
3.3.4
Programming field 3 : Select CAN address
This address is valid only for Cristec CAN Protocol
It is possible to parallel several modules (one master A with a maximum of three slaves A1, A2 et A3), all the
slaves X will synchronize with the master X. Each module must have a different address.
Specific
Specific
OFF
OFF
Setting
CHARGER /
Setting
CONVERTER_Frame1
CAN address
0
0x0002 9000 master A
0x0002 9001 master B
1
0x0002 9002 master C
2
0x0002 9003 master D
3
0x0002 9004 slave A1
4
0x0002 9005 slave B1
5
0x0002 9006 slave C1
6
7
0x0002 9007 slave D1
12V/24V
36V/48V
12V/24V
36V/48V
Programming with UNI-DISPLAY-R
REFRESH
mode
0
OFF
1
OFF
2
ON
3
ON
Setting
12V/24V
0H
36V/48V
12V/24V
0H
36V/48V
Programming with CAN-Bus
BOOST
mode
OFF
ON
OFF
ON
CHARGER /
CONVERTER_Frame1
CAN address
8
0x0002 9008 slave A2
0x0002 9009 slave B2
9
0x0002 900A slave C2
10
0x0002 900B slave D2
11
0x0002 900C slave A3
12
0x0002 900D slave B3
13
0x0002 900E slave C3
14
15
0x0002 900F slave D3
0H
0H
38