6.5 Installing the air barrier
Unscrew the frontal bottom screw of the housing
using the equipped hexagonal wrench. Remove the
frontal flange and the standard glass.
Fig. 9
Insert the tempered glass in the air barrier seat after
the right fitting of the gaskets. The gaskets on the
frontal part of the housing are 3.
Close the housing frontal flange being careful not to
damage the closing gaskets.
Insert the compressed air tube in the relevant 1/4"
GAS pipe fitting on the air barrier.
Fig. 10
8
We recommend using the optional filter unit for
cleaning the compressed air (NXFIGRU).
Fig. 11
NXFIGRU
The maximum air pressure to be supplied to the air
barrier is 2.5bar. The following experimental data give
the effective air consumption, for calculating the size
of the compressor.
AIR BARRIER, SIZE OF THE COMPRESSOR
Compressed air pressure (bar) Air barrier consumption
1
1.5
2
2.5
Tab. 1
(m³/h)
7
10
12
14