Installation height
The installation height must be between 0.8 m and
1.2 m.
Leave at least 6 cm above the mount so that you can
open and close the cover.
Adjusting the detection zone
Install the detector so that moving objects or people
pass through the detection zone.
The detector is protected against light interference.
However, excessively bright light renders it unstable.
We recommend that you prevent the detector
from being dazzled by direct or refl ected sunlight,
if possible.
Detection lobe
Top view with a detection angle set to position 1:
IR: infrared detection
HF: microwave detection
8
0,8<h<1,2m
YES
PREVENT IF POSSIBLE!
12 m
10
8
6
4
2
0
8
6
4
Copyright © 2022 Somfy Activités SA. All rights reserved.
> 6cm
NO!
IR
HF
2
0
2
4
6
8m