Soliris Io + My In Detail; Installation; Installation Recommendations; Mounting The Sensor Bracket - SOMFY Soliris io+MY Notice

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Soliris io + MY
1.6. SOLIRIS IO + MY IN DETAIL
Description
E
Sun sensor
F
Anemometer
G
Protective housing
H
Mounting bracket
I
PROG button
J
Sun LED
K
Wind LED
Y
Sun potentiometer
M
Wind potentiometer

2. INSTALLATION

2.1. INSTALLATION RECOMMENDATIONS

• Choose a location with maximum wind detection and which is not hindered by obstacles: install the
sensor in a location that is not sheltered from the wind
• Choose a sunny location where sunshine detection is compatible with wind detection.
• Install the sensor near the product which it controls.
• Never install the sensor underneath the motorised product or
under artificial lighting.
• Always fit the sensor with the anemometer (F) on top!
͉
The articulated structure of the Soliris io + MY sensor enables it to be
mounted on walls or roofs with a slope of up to 15°.

2.2. MOUNTING THE SENSOR BRACKET

1] Drill two holes, 38 mm apart and horizontally aligned.
2] Push the plugs (D) in (use the plugs supplied or a suitable model
for the medium)
3] Remove the protective housing (G) and then fix the sensor
mounting bracket (H) to the wall using the screws (C) supplied.

2.3. WIRING

2.3.1. Soliris io + MY wiring
Attention
Perform disassembly and wiring operations away from any dust, moisture or foreign bodies to maintain
tightness.
Copyright
2020 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
E
G
H
Y
M
1]
2]
D
3]
EN
F
I
J
K
C
H
3

Publicité

Table des Matières
loading

Table des Matières