Precautions for use
Vertical installation
Install the detector vertically, with the upper detection
beams parallel to the ground.
If the detector is at an angle, the detection reliability
may be reduced.
The areas scanned by the external wall
movement detectors should not intersect.
Installation height
The installation height must be between 0.8 m
and 1.2 m.
Leave at least 6 cm above the mount so that you can
open and close the cover.
Adjusting the detection beam
Install the detector with the upper and lower detection
beams parallel to the wall.
Caution: the rendering of the wall may affect the
correct positioning of the detector.
Avoid the lower detection zone facing reflective
surfaces (puddle, window, etc.).
The position of the detector must be chosen so
that the beams are not broken by moving objects
(branches, bushes, washing on a line, flags or
swinging shutters). If unstable objects cannot be
avoided, consult the Troubleshooting section at the
end of this manual.
Detection lobe at 0°
12 m
10
0
1 m
2 m
66
8
6
4
OUI
YES
0,8 < h < 1,2 m
OUI
YES
2
0
2
Copyright © 2015 Somfy SAS. All rights reserved.
> 6 cm
NON !
NO!
NON !
NO!
4
6
8
NON !
NO!
NON !
NO!
10
12 m