Messages; Smart Remote - Tuxhorn tubra-eTherm S Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.5.3 Messages

In the Status / Messages menu, error and warning messages are indicated.
During normal operation, the message Everything OK is indicated.
A message consists of a short text about the fault condition.
Display
!Sensor module
!Sensor fault
!Fan
In case of an error, the control LED starts flashing red and a message is indicated in
the status display. In case of a sensor or fan error, the system will switch off and a
message will appear on the display.
If the bus communication is defective, the control LED is red.
After the error has been removed, the error message will disappear.
Description
Bus communication interrupted (sensor
module)
Sensor defective
Fan defective
4.6

Smart Remote

The Smart Remote function is used for remote access to the controller via a
4-state signal.
DIn1 and DIn2 of the controller are digital switching inputs. The switching states are
On (contact closed) and Off (contact open).
Mode
DIn1
SR off
On
Normal operation
Off
SR Plus
Off
SR on
On
The Smart Remote function is automatically deactivated when the power control
is carried out via the sensor module variant.
In the SR off operating status, the electric heating is switched off regardless of the
excess measured. The internal backup heating and the booster are blocked.
During normal operation, the automatic control is carried out depending on the
excess measured and with optional internal backup heating.
In the SR Plus operating status, the electric heating is operated at nominal power
regardless of the timer and the excess measured. Operation is stopped when the
switch-off temperature of the internal backup heating is reached at the allocated
sensor. Without internal backup heating, operation is stopped when the store max-
imum temperature is reached at S1.
In the SR on operating status, the electric heating is operated at nominal power
regardless of the timer and the excess measured until the store maximum temper-
ature is reached at S1.
DIn2
Off
Off
On
On
21

Publicité

Table des Matières
loading

Table des Matières