III - SETTING IN OPERATION - INSTALLATION
3.1 Connection
a.
Turn the clock upside down on a table.
Unscrew the anti-theft locking screw.
Push the wall holder opposite the two
arrows to unclip it.
Remove the wall holder on the back of the
clock.
b.
Connect the Ethernet network on the RJ45
connector.
Ethernet cable category: 4, 5 or 6 (buildings). In the latter case, use a female wall
connector with a small flexible male/male RJ45 cable.
The
type of synchronisation will have to be programmed in the Technician Menu (see
page 29), particularly the Multicast address which must be the same as that of the server
(by default 239.192.54.01).
3.2 Installation
Setting of the table bracket (if supplied)
(in the 2 notches of the wall bracket).
Fit the wall bracket using the plugs and screws supplied.
Clip the clock in place on the bracket and secure with the anti-theft locking screw provided
(see diag.2).
Remove the protective sheet from the front panel and use the anti-static cloth to clean the
clock.
Mounting on vertical bracket or ceiling bracket :
Cristalys or Opalys clocks can be installed on various types of brackets (ref. 938901,
938907 and 938908). See the installation manual delivered with the bracket.
143
100
Reset
Sel.
Anti-theft locking
screw
Diag.: 2