b Press [+] until the required minute is displayed. To synchronise your clock to the nearest
second, select the current minute +1 and as the minute pips, validate by pressing [SEL] ;
The internal second counter is then reset to zero and starts up.
3. a Having validated the minutes : the year flashes.
b Press [+] until the current year is displayed.
4. a Validate the year by pressing [SEL] : the month flashes.
b Press [+] until the required month is displayed.
5. a Press [SEL] to validate the month : the day flashes.
b Press [+] until the chosen day is displayed (Scrolling of the days takes
account of the month and year selected (leap years)).
6. a To conclude time setting, press the [SEL] button.
Caution : At any time by holding down [SEL] then, pressing [+] quickly,
will return you to normal display mode. If no buttons are pressed for a
period of over 10 minutes, the clock automatically returns to normal time display mode.

4.2 Radio synchronised Clock

If the quality of reception is good, the time on the clock will be set automatically. In zones where
the radio signal is difficult to receive, clock can be set on time manually, following the procedure
described in the previous chapter.

4.3 AFNOR or impulses slave Clock

The time on the AFNOR/Irig-b slave clock will be set automatically.
After a reset or a time setting, the clock search each minute, during 20 seconds, until it get
synchronised.
Minute or ½ minute slave clocks must be set to the time of time distribution network.
Remark : See the chapter "Technician Menu" page 33 to parameter to time distribution.
Caution : In case of no AFNOR synchronisation message :
- After setting up or after changing the batteries, the time will not be running and the clock
will only display two points.
It is always possible to modify the time setting but the time will not be running and the cock will
only display the two points.

4.4 DHF clock

Caution: when installing the clock, the master clock Sigma or the transmitter must be set to INIT
mode.
DHF clocks are self-setting clocks.
- After inserting the batteries, the clock displays INIT for 5 seconds then 00:00.
The synchronisation search is limited to 4 hours. Beyond, the clock stops searching and
displays only 2 fixed dots. A press on one of the keys will restart the synchronisation search
for 4 hours.
It memorises the address of the transmitter and switches to normal mode automatically when
time is received.