5.5.4 FINISHING
Refer to "FINISHING" section for complete instructions regarding
mantel requirements and installations, glass media placement,
glass door and upper and lower louvre attachments.
6.0 FINISHING
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
f i r e - p a r t s . c o m
FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING.
6.1
DOOR INSTALLATION
THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO
FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR
OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR
SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.
BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO
THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.
6.2
END DOOR INSTALLATION (PENINSULA INSTALLATION ONLY)
DOOR OPENING AND CLOSING: The upper louvres must be removed to allow the door to be opened or
closed. To access the lower door latch, open the valve control door. Release the top and bottom door latches,
located at the right side of the door.
Ensure that the door is properly clipped onto the steel lip to prevent overheating, glass breakage and / or
discoloration of the upper trim. To install the door(s), hook it over the steel lip located above the door opening.
Secure with screws along the bottom of the door. Tighten screws snugly. Do not over-tighten.
DOOR
All manuals and user guides at all-guides.com
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED.
REMOVED, CRACKED, BROKEN OR SCRATCHED.
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.
STEEL LIP
WARNING
!
RISK OF FIRE!
WARNING
!
DRYWALL
DRYWALL
5" MIN
72.1A
75.1
W415-1028 / A / 08.13.12