Removal
Never connect another user to the second line.
Incorrect Attachment
N !
Fig. 8
Incorrect attachment
3.2.5

Workman Twin Leg PFL Alternate Installation

The Workman Twin Leg PFL can also be installed without the use of securing straps. However, to
account for PFL rotation during a fall arrest, additional free fall of 2 ft must be included in the fall clear-
ance calculation and applied to the free fall limit.
(5)
Don the harness as outlined by the instructions supplied
with it.
NOTE:
If the harness does not have lanyard keepers (to
secure the PFL's lanyard leg(s) when not used), then install the
keepers included with each Workman Twin Leg PFL. These
keepers are to be placed on the front harness torso straps near
the worker's chest.
(6)
Use the keepers to secure the lanyard leg not in use.
(1)
Take off the harness.
(2)
Undo the securing straps.
(3)
Press both tabs together simultaneously.
(4)
Pull on the D-ring.
Self-Retracting Lanyard