The time is adjusted by using the [UP], [DOWN] keys.
Pressing the [SET] key enters the hours. The minutes are set
by using the [UP], [DOWN] keys.
Pressing the [SET] key once enters the minutes and moves
the display into the Set Hardness mode. This can be
displayed in PPM, degrees German, or degrees French
depending on the model of softener.
Hardness in °dH
2.
Setting the supply water hardness
The display default is 16 °dH (typical hardness level) which
indicates a setting suitable for the supply water hardness
which has to be measured and entered during the set up of
the softener. Use the [UP] [DOWN] keys to adjust the setting
to match that of the one you obtained / identified with the
water hardness test kit.
Pressing the [SET] set key once enters the hardness and
moves the display to Set Recharge Time Mode.
3.
Setting the recharge time
To operate effectively, your water softener needs to
regenerate periodically (dependent on the hardness of the
supply and amount of water used). The default time of day
when this is to occur is 2:00 a.m. To alter this setting use the
[UP] [DOWN] keys.
Initial display on start up »
TIME «
[UP]
[DOWN]
[SET]
» RECHARGE TONIGHT
TIME «
GB
Pressing the [SET] key once enters the recharge time and
moves the display into service mode.
3
Installation Guidelines

3.1 Setup requirements

National guidelines and regulations:
Observe all applicable installation regulations, general
guidelines, hygiene requirements, and technical
specifications.
The hard water to be fed into the unit must always meet the
specifications of the national Drinking Water Ordinance or EU
Directive 98/83/EC.
The total dissolved iron and manganese may not exceed 0.1
mg/l.
The hard water to be fed into the unit must always be free of
air bubbles.
Frost protection and ambient temperature:
The installation site must be free of frost and kept free of
chemicals, paint, solvents and fumes
The ambient temperature should not exceed 40°C, even
before the machine is started
Please avoid direct heat sources, e.g. radiators and exposure
to sunlight
General safety:
The rated mains power (see 1.4 Technical Data) and the
requisite inlet water pressure must be present at all times.
No protection against a lack of water is provided.
This must be installed on-site if required.
Overpressure and fluctuation protection:
Attention: Water pressure must never exceed the unit's
maximum 8.0 bar
If the network water-pressure is higher than 6.0 bar (or you
are unsure about pressure), a pressure reducer (pressure
reducing valve) must be installed upstream of the unit
During pressure fluctuations or surges, the sum of the
pressure surge and the standing pressure is not to exceed the
nominal pressure
4
» SERVICE«
MU1H-1420 GE23 R0420