Nominal capacity
(EN 14743) :
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Capacity salt reservoir:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Max. salt consumption per
regeneration:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Max. water consumption per
regeneration:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Protection class:
Dimensions:
Height
KS30E-30, KS30I-30
KS30E-60, KS30I-60,
KS30I-80
Width
KS30E-30, KS30I-30
KS30E-60, KS30I-60,
KS30I-80
Depth
KS30E-30, KS30I-30
KS30E-60, KS30I-60,
KS30I-80
Height input/output-h:
KS30E-30, KS30I-30
KS30E-60, KS30I-60
KS30I-80
Operating weight, approx.:
KS30E-30, KS30I-30
KS30E-60, KS30I-60,
KS30I-80
Disinfection unit:
KS30E-30, KS30E-60
KS30I-30, KS30I-60,
KS30I-80
1.5 Options
For Options visit homecomfort.resideo.com/europe
MU1H-1420 GE23 R0420
GB
³
30 m
x °dH/ 54 °fH/
540 ppm
³
60 m
x °dH/107 °fH/
1070 ppm
³
85 m
x °dH/151 °fH/
1510 ppm
12 kg
25 kg
25 kg
1.5 kg
2.5 kg
3 kg
85 l
125 l
145 l
IP51
536 mm
808 mm
808 mm
270 mm
270 mm
270 mm
483 mm
483
483 mm
400 mm
670 mm
670 mm
40 kg
65 kg
70 kg
-
yes
yes
3
2
Quick Operation
2.1 Display and control elements
[UP]
[DOWN]
= Moves cursor changes
entries
Note:
In the programming mode the respective >target value<
flash.
2.2 Standard settings
On first powering up the softener the digits of the display will
flash while the valve rotates to service position.
The valve can be heard moving and this can take a few
minutes.
On locating service position the display will prompt the
installer to set the time.
Go to section to set the time and hardness settings.
2.3 Programming procedure
1.
Setting the time of day
The first two digits (00) of the display will flash prompting the
installer to set the time.
The display shows:
the current time
the remaining capacity in
20% bars
[SET/
[RECHARGE]
RETURN]
= Confirms
= Programming
entries
recharge
tonight
KaltecSoft