Converting for Use with Natural Gas or
Propane Gas
This range arrives from factory adjusted for use with
natural gas. If using LP/propane gas is desired, range
must be converted.
WARNING
To avoid electric shock that can cause personal injury
or death, disconnect main electrical supply to range
before servicing.
Converting Type 1 Pressure Regulator for Use with
LP/ Propane
1. Remove pressure regulator cap using a
wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Cap must show "LPG10" or "LP10".
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of regulator.
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator cap using a
wrench.
2. Reverse pressure regulator cap.
• Cap must show "LP".
7
/
inch
8
3. Place pressure regulator cap on pressure regulator
and tighten.
9
7
/
inch
8