Amana ARG7300 Serie Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Converting Broiler Burner for Use with LP\Propane
1. Locate orifice spud attached adjacent to pressure
regulator and remove for later use.
• Orifice spud used for LP/propane gas is silver and
is stamped "58".
Orifice Spud
Natural Gas—52
LP/Propane—58
2. Open oven door and locate broiler burner on oven
ceiling.
• Remove oven door to make conversion easier. See
Removing Oven Door section.
3. Remove 2 screws securing front of burner to oven
ceiling and remove broiler.
• Be careful not to damage ignitor while removing
broiler.
4. Unscrew natural gas burner spud stamped "52" with
5
/
inch socket wrench and replace with LP/propane
16
burner spud stamped "58".
• Attach unused burner spud near regulator for future
use.
5. Reinstall broiler and, if necessary, oven door.
Converting Type 1 Pressure Regulator for Use with
Natural Gas
1. Remove pressure regulator cap using a
wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Insert must show "NAT" or be blank.
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of regulator.
Converting Type 2 Pressure Regulator for Use with
Natural Gas
1. Remove pressure regulator cap using a
wrench.
2. Reverse pressure regulator cap.
• Insert shows "NAT" or is blank.
3. Place pressure regulator cap on pressure regulator
and tighten.
Converting Surface Burners for Use with
Natural Gas
1. Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside.
• Gas valve and orifice hood are visible after burner
control panel are removed.
4. While facing range front, turn orifice hoods clockwise
1½ to 2 turns.
• Use ½ inch, 90° offset crescent wrench.
5. Reassemble Burner control panel after adjusting air
flow to surface burner flame.
• See Adjusting Surface Burner Flame section.
Converting Oven Burner for Use with
Natural Gas
1. Remove storage drawer.
• Removing Storage Drawer section.
2. Locate and remove 2 screws attaching Z-shaped
cover plate.
• Cover plate located in center, rear of storage drawer
cavity.
• Removing cover plate exposes oven burner orifice
and air shutter.
3. Turn orifice hood counterclockwise 2 full turns.
4. Replace cover plate and storage drawer.
7
/
inch
Converting Broiler Burner for Use with
8
Natural Gas
1. Locate orifice spud attached adjacent to pressure
regulator and remove for later use.
• Orifice spud used for natural gas is silver and is
stamped "52".
2. Open oven door and locate broiler burner on oven
ceiling.
• Remove oven door to make conversion easier. See
Removing Oven Door section.
3. Remove 2 screws securing front of burner to oven
ceiling and remove broiler.
• Be careful not to damage ignitor as you remove
broiler.
7
/
inch
8
4. Unscrew LP/propane burner spud stamped "58" with
5
/
inch socket wrench and replace with natural gas
16
burner spud stamped "52".
5. Reinstall broiler and, if necessary, oven door.
11