AC PARALLEL OPERATION
Before connecting an appliance to either generator, make sure that the
appliance is in good working order and that its electrical rating does not exceed
that of the receptacle.
Most motorized appliances require more than their electrical rating for startup.
When an electric motor is started, the overload alarm indicator (red) may come
ON. This is normal if the overload alarm indicator (red) goes OFF within 4
seconds. If the Oil Alert/Check indicator (red) blink continuously, consult an
authorized Honda servicing dealer.
During parallel operation, the Eco Throttle switch should be in the same
position on both generators.
1. Connect the parallel cable between the two EU32i generators following the
instructions supplied with the cable.
2. Start the engines (see page 40) and make sure the output indicator (green) on
each generator comes ON (see page 44).
OPERATION
PARALLEL CABLE
(optional equipment)
47