74
EN 50124-1, IEC 62497,
EN 50178
Contact protection
(protection against
electric shock)
Clearances
Creepage distances
Isolation
Test voltage
Rated isolation voltage
EN 50124-1, IEC 62497,
EN 50178,
EN 61140/EN 61010-1, UL347
Ambient Conditions
Temperature class
Operating temperature
Storage temperature
Relative humidity
Altitude classes
Air pressure during
operation
Max.
1000 V AC/DC
Max.
1000 V AC/DC
Min. 60 mm
Min. 90 mm
Output against Power Supply
4 kV
Protection against
electric shock by
reinforced insulation
Max.
300 V AC/DC
TX
–40 ... 85 °C
–50 ... 90 °C
20 ... 95 %
75 %
95 ... 100 %
A1, AX
600 ...
1060 hPa
Specifications
Rated impulse voltage: 20 kV
with ZU 1030 protective covers,
ZU 1031 cable support sleeves
acc. to EN 50153 ranges I to III
CTI 600, insulant group I acc. to
EN 50123-1, EN 50124-1
100 % routine test / type test
Overvoltage category OV3,
pollution degree PD3
for EN 50178: PD2
Rated impulse voltage: 6.4 kV
EN 50125-1,
EN 50155
Limit values for continuous operation
Annual average
Occasional
EN 50125, reduced isolation level
for heights of 2000 to 4000 m AMSL