2.4 Specification
(The data on the type plate apply)
Type
Part no.
Nominal content
Content, bare-tube HE
Heat pump operation
Content, bare-tube HE
Solar operation
Weight, dry
Height when tilted
Permiss. operating pressure, DHW
Permiss. operating pressure, heating medium
Test pressure (type test), cylinder and HE
Max. DHW temperature
Standby heat loss *
Bare-tube HE, heat pump operation
Heating surface
Pressure drop at 1 m³/h
Permiss. operating pressure
Bare-tube HE, solar operation
Heating surface
Pressure drop at 1 m³/h
Permiss. operating pressure
* In accordance with DIN 4753 at
mm
MPa (bar)
MPa (bar)
MPa (bar)
kWh/24 h
hPa
(mbar)
MPa (bar)
hPa
(mbar)
MPa (bar)
= 65 °C and at
= 20 °C
Water
Air
SBB 301 WP
SBB 302 WP
221360
221361
l
300
l
18,6
l
kg
160
1780
1 (10)
1 (10)
2 (20)
°C
95
2,0
m²
3,2
54
1 (10)
m²
SBB 401 WP SOL
221362
300
400
28,4
23,9
7,5
188
222
1780
1950
1 (10)
1 (10)
1 (10)
1 (10)
2 (20)
2 (20)
95
95
2,0
2,3
4,8
4,0
77
66
1 (10)
1 (10)
1,4
24
1 (10)
SBB 501 WP SOL
227534
500
29,8
7,5
275
2035
1 (10)
1 (10)
2 (20)
95
2,6
5,0
80
1 (10)
1,4
24
1 (10)
13