12. Troubleshooting
Fault
Cause
The appliance does not
The heating element/
heat up.
temperature selector is
faulty.
The ON/OFF indicator
The ON/OFF indicator is
does not illuminate al-
faulty.
though the appliance is
switched on.
The flow rate is reduced
The throttle screw is con-
when filling the appli-
taminated.
ance or drawing cold
water.
The tap leaks.
A sealing element is
faulty.

13. Maintenance

WARNING Electrocution
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.

13.1 Servicing the taps

f When carrying out maintenance work on the taps, reduce
f
the water supply by using the throttle screw. Be aware that
the throttle screw is not permanently watertight (see chapter
"Commissioning").

13.2 Checking the earth conductor

f In accordance with BGV A3, check the earth conductor on
f
the heating element and the earth conductor contact on the
power cable.

13.3 Replacing the power cable

The power cable must be replaced by an authorised contractor
with the original spare part (part no. 020671).
24
| EBK | KBA

14. Specification

Remedy

14.1 Dimensions and connections

Check the heating el-
ement/temperature
EBK 5 K
selector and replace the
relevant component if
necessary.
Replace the ON/OFF in-
dicator.
Clean the throttle screw.
Check the sealing sys-
tems and replace the
relevant sealing element
if necessary.
KBA 5 KA
c01
i13
325
i13
c01
325
i13
c01
Cold water inlet
Male thread
Wall mounting
bracket
197
105
146
+15
197
105
175
+15
EBK 5 K KBA 5 KA
G 1/2 A
G 1/2 A
www.stiebel-eltron.com