ENGLISH
3.0 Before installation
3.1 Distance to infl ammable material
See fi g. 1.
3.2 Foundations
You need to make sure the fl oor is suitable for the entire
installation. See "2.0 Technical data" for specifi ed weight.
Flooring that is not attached to the foundation – "fl oating fl oors"
– must be removed beneath the product.
Remember: If a steel chimney resting on the insert is being
used, the weight of the steel chimney must be taken into
account.
NB: It is extremely important to ensure that the product
is stable; the surface it is installed on must be completely
infl exible.
3.3 Floor covering
We recommend the removal of any fl ooring that is not attached
to the foundation ("fl oating fl oors") beneath the installation.
Any fl oor covering of infl ammable material, such as linoleum,
carpets, etc. must be removed from under the installation area.
3.4 Floor plate
A plate made of steel or some other suitable non-infl ammable
metal (optional extra) is placed in front of the fi replace.
Contact your local building authorities regarding restrictions and
installation requirements.
3.5 Air circulation requirements
Air shall be allowed to circulate between the insert and the
brickwork.
Important! Ensure that air vents in the room where the
fi replace is located are not blocked.
3.6 External air
A fl exible supply tube for combustion air (optional equipment,
art. no. 51012164) can be installed through a hole in the back
of the surround, or else through the hole cut where marked in
the bottom plate.
6
3.7 Steel chimney
If a top-mounted steel chimney is used, an uninsulated pipe is
fi tted from the insert to approximately 10 mm over the top grate.
A 50 mm off set pipe (optional extra) must be used. Then fi t the
steel chimney in accordance with the operating instructions.