CONNECTING THE POWER SUPPLY
Cable colour
Power supply 24Vac
Defined by the installer
Defined by the installer
Yellow/Green
Power supply 100Vac, 120Vac, 220Vac, 230Vac
Blue
Brown
Yellow/Green
Tab. 13
30
Terminals
~/24Vac
~/24Vac
(N) Neutral
(L) Phase
6.6 Connecting alarms, remote
reset and relays
All signal cables must be grouped together
by means of a cable tie.
CONNECTION OF THE ALARM INPUTS AND RELAYS
Connectors
Terminals
J6
AL1, COM
RST, RST
J8
RL1A, RL1B
RL2A, RL2B
Tab. 14
RST
RST
COM
AL1
Fig. 16
Description
Self-powered alarm input
fitted in the common
terminal
Remote reset
Dry output contacts, can
be activated by alarm or
by user control
Contact for washer pump
activation
J6
MNVCMPXHDC_2222_EN