Starting / Stopping The Engine - Stihl MS 362 C-Q Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fitting the cover plate
2
2
1
N
Place the cover plate (1) in position,
engage the two tabs (arrows), and
secure it with the screws (2).
MS 362 C-Q
All manuals and user guides at all-guides.com
Starting / Stopping the
Engine
Positions of the Master Control lever
STOP
0
Stop 0 – engine off – ignition is switched
off
Operating position F – engine is
running or can start
Warm start n – this position is for
starting the warm engine – the Master
Control lever returns to the operating
position when the throttle trigger is
squeezed
Cold start l – this position is for
starting the cold engine
Adjust Master Control lever
To adjust the Master Control lever from
the operating position F to cold start l,
press and hold down the throttle trigger
interlock and throttle trigger
simultaneously – set Master Control
lever.
To set the Master Control lever to warm
start n, first set it to cold start l, then
push the Master Control lever into the
warm start n position.
Switching to the warm start n position
is only possible from the cold start l
position.
Simultaneously pressing the throttle
trigger interlock and blipping the throttle
trigger causes the Master Control lever
to jump from the warm start n position
to the operating position F.
To switch off the engine, set the Master
Control lever to Stop 0.
Position choke shutter closed l
if engine is cold
if the engine stalls during opening of
throttle after starting
if the fuel tank has run empty
(engine stalled out)
Position starting acceleration n
if engine is warm (once the engine
has been running for approx. one
minute)
when the engine has turned over for
the first time
after ventilation of the combustion
chamber, if the engine was flooded
English