• Technical programming
14.8.2
Boiler Temperature units
Enter
Temperature
ºC
Canc
Enter
14.8.3
Boiler Temperature
In this screen we can see the actual temperature of the boiler, and adjust the temperature that we
wish for it. On the left of the display the actual temperature of the boiler can be seen. On the right
hand and flashing, the temperature to which we wish to adjust the boiler. With buttons "+" and "-"
we adjust this setting; with "enter" we accept the value, and proceed to the next adjustment.
The temperature can be set between 60 and 107ºC. The adequate temperature depends on the type
Enter
Boiler Temperat.
T.act.
Set Temp
Canc
Enter
14.8.4
Stand-by state
After the machine has been idle for 4 minutes, to compensate the loss of temperature in the
espresso group, the temperature of the boiler will be increased accordingly with this parameter.
This is the "StandBy DT", which can be adjusted between 0 and 5ºC. With buttons "+" and "-" we
Enter
StandBy DT.
Set DT
Canc
Enter
14.8.5
Espresso group enabling/disabling
The next screen enables the Express group. This setting must be set to "enabled", as to allow the
Enter
Express Group
Enabled
Canc
Enter
14.8.6
Grounds counter
We will now adjust the "Grounds program". This is a setting that enables a counter that takes care
of not overflowing the grounds container. It should be adjusted to 90 when using the standard inner
container of the machine. When the machine has brewed that number of services involving
espresso, it will prevent any more brewing of beverages involving espresso until the coffee
grounds tray is emptied.
If we are using the cabinet for the machine, we have to set the Grounds program to 0. This will
turn off the counter and allow uncounted services to be brewed.
With buttons "+" and "-" we adjust this setting; with "enter" we accept the value, and proceed to
the next adjustment.
English
All manuals and user guides at all-guides.com
This parameter sets the units for the temperature of the
+
boiler. With buttons "+" and "-" we change between
Celsius "ºC" and Fahrenheit "ºF"; with "enter" we accept
Temperature
the selected language, and proceed to the next adjustment.
ºF
-
T.act.= Actual Boiler Temperature
Set Temp= Temp. to which boiler is set
Recomended 97ºC
Recomended 4ºC
express group to work. With buttons "+" and "-" we change
+
between "enabled" and "disabled"; with "enter" we accept
the selected language, and proceed to the next adjustment.
Express Group
Disabled
-
of coffee beans that will be used in the
machine. A recommended value is 97ºC.
adjust this setting; with "enter" we accept the
value, and proceed to the next adjustment.
38