Application and operation

=
WARNING
Live parts. Electric shock hazard! The enclosure
cover must not be damaged. The enclosure cover
must be closed tightly. Observe tightening torque.
=
WARNING
Risk of injury! Actuators must be undamaged.
Actuators must be firmly mounted. Observe
tightening torque.
=
WARNING
Incorrectly installed wire installations can lead to a
malfunction of the device. Risk of injury! Observe
the specified distances for wire support. Observe
maximum actuating forces for the levers. Observe
country-specific standards and directives.
=
CAUTION
High temperatures. Risk of burns! For short-circuit
protection, use fuse size 10 A (gG/gL). Observe per-
mitted ambient temperatures.
N.B.
Only authorized personnel are allowed to carry out mounting, electri-
cal connection and start-up. Mounting must be carried out with usual
operation temperature. Any mounting position is possible. Reconstruc-
tion and alterations to the device which might affect the safety function
are not allowed. The described products have been developed in order
to assume safety functions as a part of an entire plant or machine. A
complete safety system normally covers sensors, monitoring modules,
indicator switches and concepts for safe disconnection. For the inte-
gration of the device in the entire system: strictly observe and respect
the control category determined in the risk assessment. Therefore, a
validation according to EN ISO 13849-2 or EN 62061 is necessary. Fur-
thermore, the Performance Level according to EN ISO 13849-1 and
SIL CL Level according to EN 62061 can be lower than the single level
because of the combination of several safety components and other
safety-related devices, e.g. by serial connection of switches.
It is the responsibility of the manufacturer of a plant or machine to
guarantee the correct general function. We reserve the right to make
design changes in line with technological progress. New claims for
guarantee, warranty or liability cannot be derived from this document
beyond the general terms and conditions of delivery.

Maintenance and troubleshooting

=
WARNING
Live parts. Electric shock hazard! Do not repair
defective or damaged devices. Replace them.
Alternative: Repair of defective device by trained
personnel in agreement with steute and with
steute spare parts.
=
WARNING
Live parts. Unsuitable greases or lubricants can
lead to functional failure and loss of the protec-
tion class. Electric shock hazard! Do not use any
greases nor lubricants.
With careful mounting as described above, only minor maintenance is
necessary. We recommend a routine maintenance as follows:
1. Check for correct switch function by checking the pull-wire function
and the wire-break detection.
2. Removal of dirt.
3. Check sealing of the cable or conduit connections.
4. Check fix position of the actuator.
Cleaning
=
WARNING
Live parts. Electric shock hazard! Clean in ac-
cordance with degree of protection IP65/66/67.
- Clean by hand with a hand brush or cloth.
- Do not use knives or sharp-edged tools.
- Do not use any cleaning agents containing solvents.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.
Français
Utilisation des instructions de montage et de câblage
Groupe cible: personnel autorisé et compétent.
Toutes les manipulations décrites dans cette notice d'installation ne
doivent être effectuées que par du personnel formé et autorisé par la
société exploitante.
1. Lire et comprendre les instructions de montage et de câblage.
2. Respecter les règles de sécurité et de prévention des accidents
en vigueur.
3. Installer l'appareil et le mettre en service.
La sélection et l'installation des appareils et leurs intégrations dans
les systèmes de commande exigent une connaissance approfondie
4 / 28

Publicité

Table des Matières
loading

Table des Matières