Control Unit - Nice MhouseKit WU200S Instructions Et Avertissements Pour L'installation Et L'utilisation

Kit complet pour automatiser un portail battant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

"SAFE" LED
Off
3 quick flashes and 1
second pause
1 very slow flash
1 slow flash
1 quick flash
1 very quick flash
Always on
9.6.2 - Flashing indicator
Quick flashes
Status
1 flash
Error on ECSbus
1 second pause
1 flash
2 flashes
Triggering of a photocell
1 second pause
2 flashes
3 flashes
Action of the "motor force" limiting device
1 second pause
3 flashes
4 flashes
Activation of the STOP input
1 second pause
4 flashes

9.6.3 - Control unit

The control unit has a series of LEDs, each of which can give particular
signals both during regular operation and when there is a problem, see
Table 13.
ECSBus LED [A]
Status
Off
Malfunction
On
Serious malfunction
One flash every second
All OK
2 long flashes
The status of the inputs has
changed
TABLE 11
STATUS
The photocell has no power supply or is
faulty
Device not recognised by control unit
The RX is receiving optimum signal
The RX is receiving good signal
The RX is receiving poor signal
The RX is receiving bad signal
The RX is receiving no signal
TABLE 12
TABLE 13 (fig. 44)
ACTION
Check that on the terminals of the photocell there is a voltage
of approximately 8-12 Vdc; if the voltage is correct, it is likely
that the photocell is faulty.
Repeat the recognition procedure on the control unit. Check
that all photocell pairs on the ECSBus have different addresses
(see Table 8)
Normal operation
Normal operation
Normal operation but it is necessary to check the TX-RX align-
ment and correct cleaning of the glasses
It is at the limit of normal operation. It is necessary to check the
TX-RX alignment and correct cleaning of the glasses
Check for any obstruction between TX and RX. Check that the
LED on TX emits a slow flashing. Check the TX-RX alignment
During the manoeuvre the flashing indicator flashes once every second.
When something is wrong the flashes are more frequent (every half sec-
ond); the light flashes twice with a second's pause between flashes, see
Table 12.
Action
At the beginning of the manoeuvre, the verification of the devices
present does not correspond to those learned; check and possi-
bly try to redo the learning (9.3.3 "Recognition of other devices" ).
Some faulty devices may be present; check and replace them.
At the start of the manoeuvre, one or more photocells are pre-
venting movement; check to see if there are any obstacles. Dur-
ing the movement, although the obstacle is effectively present, no
action is required.
During the movement, the gate experienced excessive friction;
identify the cause.
At the start of or during the manoeuvre, the STOP input was acti-
vated; identify the cause.
44
Action
Make sure there is power supply; check to see if the fuses are blown; if nec-
essary, identify the reason for the failure and then replace them with others of
the same type
There is a serious malfunction; try switching off the control unit for a few sec-
onds; if the condition persists, it means there is a malfunction and the circuit
board has to be replaced.
Normal operation of control unit.
This is normal when there is a change in one of the inputs: OPEN, STOP, trig-
gering of photocells or the radio transmitter is used
A
B
C
D
E
F
English – 27

Publicité

Table des Matières
loading

Table des Matières