To memorise DS1:
01. Press P1 [B] (fig. 41) for at least 3 s. When the LED P1 [A] (fig. 41)
lights up, release the key.
02. Within 10 s, type in the factory combination 11 (or the secret combi-
nation, if the factory combination has been changed), and press any
of the keys A, B or C on the DS1 selector switch for at least 3 s.
If the procedure was memorised correctly, the P1 LED will flash 3
times.
03. If there are other selector switches to memorise, repeat step 2 within
another 10 seconds; otherwise, the memorisation will stop automati-
cally.
Mode 2 memorisation – with this memorisation, the commands that can
be sent by pressing the A, B or C buttons on the DS1 selector switch are
those listed in table 9.
In Mode 2 each key requires its own memorisation phase.
To memorise DS1:
01. Press P1 [B] (fig. 41) on the control unit, the same number of times
as your desired command, according to Table 14 (e.g. 3 times for
the "Open Only" command).
02. Check that LED P1 [A] (fig. 41) emits a number of quick flashes
which are equal to the selected command.
03. Within 10 s, type in the factory combination 11 (or the secret combi-
nation, if the factory combination has been changed), and press the
desired key for memorisation on the selector switch for at least 3 s.
If the procedure was memorised correctly, the P1 LED will flash slow-
ly 3 times.
Symptoms
The radio transmitter is not emitting
a signal (the LED [A] is not lit)
The manoeuvre does not start and
the LED "ECSBbus" [B] does not
flash
No manoeuvre starts and the
flashing light is off
No manoeuvre starts and the
flashing light flashes a few times
The manoeuvre starts but it is
immediately followed by a reverse
run
The manoeuvre is carried out but
the flasher does not work
42
9.6 - DIAGNOSTICS AND SIGNALS
A few devices give out special signals that allow you to recognise the
operating status or possible malfunctions.
9.6.1 - Photocells
In the photocells, there is a "SAFE" LED [A] (fig. 43) which allows you to
check the operating state at any time, see Table 11.
26 – English
TABLE 10 (fig. 42)
Probable cause and possible solution
• Check to see if the batteries are exhausted, if so replace them (see section 11.5)
• Make sure the power cable is plugged correctly into the electricity grid socket
• Check to see if the fuses [E] or [F] are blown; if necessary, identify the reason for the failure and then
replace the fuses with others of equal value
• Make sure that the commands are actually received. If the command is delivered to the OPEN input the
relative "OPEN" LED [D] must light up; otherwise if the radio transmitter is used, the "ECSBus" LED flashes
slowly twice
• Check that the STOP input is active, that is, the LED "STOP" [C] is lit. If this does not happen, check the
device connected to the STOP input
• The photocells test which is carried out at the start of each manoeuvre has not given a positive result;
check them, referring also to compliance with Table 11
• The selected force could be too low for this type of gate. Check to see whether there are any obstacles;
if necessary increase the force as described in section 9.1.1
• Make sure that there is voltage on the flashing light's FLASH terminal during the manoeuvre (being inter-
mittent, the voltage value is not important: approximately 10-30 Vac); if there is voltage, the problem is due
to the lamp; in this case replace the lamp with one having the same characteristics
A
04. After 10 s the memorisation phase terminates automatically.
Deletion – if the DS1 selector switch is memorised in Mode 1, one dele-
tion phase is sufficient and at step 3 any key, A, B or C, can be pressed.
If the selector is memorised in Mode 2 a deletion phase is necessary for
each key stored.
To delete DS1:
01. Press the P1 key [B] key (fig. 41) on the control unit and hold it
down.
02. Wait until the LED P1 [A] (fig. 41) lights up, within three seconds.
03. Type in the factory combination 11 (or the secret combination, if the
factory combination has been changed), and press the desired key
for deletion on the selector switch for at least three seconds. If can-
cellation was successful the LED P1 will flash quickly five times.
04. If there are other selector switches to delete, keeping P1 depressed,
repeat step 3 within another 10 seconds; otherwise, the deletion will
stop automatically.
For more information on the DS1 selector switch, refer to the product
instruction manual, or visit www.niceforyou.com
9.5 - TROUBLESHOOTING
Table 10 contains instructions to help you solve malfunctions or errors
that may occur during the installation stage or in case of failure.
D