Nice MhouseKit WU200S Instructions Et Avertissements Pour L'installation Et L'utilisation page 58

Kit complet pour automatiser un portail battant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parameters
Pause time
Pedestrian opening
Motor force
"OPEN" function
(*)
Original factory value
Parameters
Open input configuration on the control unit
Flash output configuration on the control unit
Motor 1 and motor 2 discharge in closure
Motor 1 and motor 2 discharge in opening
(*)
Original factory value
The parameters adjustment operation can be carried out by any one of
radio transmitters, as long as it is stored in mode 1, like those supplied
(see paragraph 10.4.1 "Mode 1 memorisation" ).
In the event that no transmitter stored in Mode 1, it is possible to memo-
rise one just for this phase, and delete it straight afterwards (see para-
graph 9.4.4 "Deleting a radio transmitter" ).
CAUTION! – When making adjustments using the transmitter, you must
allow the command unit time to recognise the radio command; in prac-
tice, the keys must be pressed and released slowly, with at least one
second of pressure, one second of release, and so on.
20 – English
TABLE 3
N° Value
1
10s
2
20s (*)
3
40s
4
80s
1
Open 1 leaf halfway
2
Fully open 1 leaf (*)
3
2 leaves partially opened to 1/4 of the full
course
4
2 leaves partially opened to half of the full
course
1
Low
2
Medium low (*)
3
Medium high
4
High
1
"Open", "Stop", "Close", "Stop"
2
"Open", "Stop", "Close", "Open" (*)
3
"Open", "Close", "Open", "Close"
4
Open only
TABLE 4
N° Value
1
Open (*)
2
Pedestrian opening
1
Flashing light (*)
2
Courtesy light
3
Gate open indicator
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
To program the parameters in Table 3:
01. Press T1 and T2 together (fig. 34) on the radio transmitter for at least
5 s.
02. Release the two keys.
03. Within three seconds, carry out the action set out in Table 4 based on
the parameter to change.
Example: to adjust the pause time to 40 s.
01. Press the T1 and T2 keys and hold them down for at least
5s
Action operation to be carried out at
step 3 in the recognition phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Action to perform
Press T1 once
Press T1 twice
Press T2 once
Press T2 twice
Press T2 three times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times

Publicité

Table des Matières
loading

Table des Matières