––– STEP 11 –––
It is recommended to keep this guide and make it available to all
users of the automation.
11.1 – Safety precautions
• Supervise the door in movement and keep at a safe
distance until the door is fully open or closed; do not
pass through the opening until the door is fully open and
stopped.
• Do not let children play near the door or with its com-
mands.
• Keep the transmitters away from children.
11.2 – Gate control
• With radio transmitter
The radio transmitter provided is already ready for use and the
four keys have the following functions (fig. 45):
45
T2
T1
Function(*)
T1 Key
T2 Key
T3 Key
T4 Key
(*) This table must be compiled by the person who programmed
the automation.
11.3 – Manually releasing and locking the gearmo-
tor (fig. 47)
WU200S are equipped with a mechanical system that allows you
to open and close the gate manually (that is, as if the gearmotor
were not present).
Manual operation must be used in the case of a power failure or
in the event of a fault in the system. In the event of a power failure,
you can use the buffer battery (optional accessory PR1).

USAGE GUIDE

• Immediately discontinue use of the automation as soon
as you notice any abnormal functioning (noises or jolting
movements); failure to heed this warning may result in seri-
ous dangers and risks of injury.
• Do not touch any part while it is moving.
• Do perform periodic checks as provided for in the main-
tenance schedule.
• Maintenance or repairs must be carried out only by quali-
fied technical personnel.
• With selector switch (optional accessory)
The selector has two positions with automatic return to the centre
(fig. 46).
T4
T3
(*) This item must be compiled by the person who programmed
the automation.
• Control with safety devices out of order
In the event of safety devices malfunctioning or being out of ser-
vice, the door may still be moved.
01. Operating the gate control (with remote control or key selec-
02. After approximately 2s the door will start moving in the "man
If the safety devices are out of order the automation must be
repaired as soon as possible.
In the event of a gearmotor fault, you can still try to use the motor
release to check if the fault lies in the release mechanism.
• Release:
01. Insert the key into one of the 2 two lateral holes located on
02. Manually move the leaf and take it to the desired position.
• Lock:
01. Insert the key into one of the 2 two holes provided, and rotate
46
Action
Function
Rotated to the right: "OPEN"
(*)
Rotated to the left: "STOP"
Stops the door movement
sectional or up-and-over
tor switch). If the safety devices give consent the door opens
normally; otherwise within 3 seconds you must try again and
keep the control actuated.
present" mode, i.e. so long as the control is maintained the
gate will keep moving; as soon as the control is released the
gate will stop.
the upper cover, and rotate it 180°, in either one of the two
directions (fig. 47);
English – 33