PROGRAMMING

5.1 - CONTROL UNIT KEYS

The control unit has four programming keys with their respective LEDs:
keys P1, P2, P3, P4 and LEDs L1, L2, L3, L4 (Fig. 12)
P1 = Step-by-Step command
P2 = slow/fast movement speed selection (Par. 5.6.1)
P3 = semi-automatic/automatic operating cycle selection (Par.
5.6.2)
P4 = radio transmitter memorisation

5.2 - PRELIMINARY CHECKS

After powering up the control unit, a few straightforward checks should be carried out:
01. Depending on the gearmotor's installation position ( to the right or left of the gate), shift the selector as shown in Fig. 13 to determine the gate's
opening direction.
02. Check on the control unit (Fig. 14) that the ECSBus led flashes normally (roughly one flash each second).
02. On the Tx and Rx photocells (Fig. 15) check that the SAFE led flashes: the type of flash is unimportant as it depends on other factors; however,
it is important that the led is not always off or always lit.
03. If all these checks are non-conforming, disconnect the power supply to the control unit and check the relevant connections of the cables. Other
useful information is contained in Chapters 9.9 and 10.
13
14
T
Fuse 1.6A T
Fus
Aerial
Aerial
L4
L4
P4
P4
P3
P3

5.3 - MEMORISATION OF CONNECTED DEVICES

On completion of the preliminary checks (Par. 5.2), the control unit must be made to recognise the devices connected on the ECSBus and Stop
terminals.
01. On the control unit (Fig. 16) press and hold button P2 for at least 3 seconds then release it.
02. Wait a few seconds for the control unit to complete the device learning phase.
03. On the control unit (Fig. 17), at the end of the recognition procedure, the Stop led must remain lit and led L2 must turn off. The ECSBus led
must flash once each second. If led L2 flashes = error (see Chapter 10).
Whenever a photocell is added to or removed from the system, or the direction selector is shifted (Fig. 13), it is necessary to repeat
the learning procedure for the connected devices.
Step
Flash
sh
Flash
OGI
OGI
OGI
ECSbus
ECSbus
Stop
Stop
Stop
SbS
SbS
bS
L1
L1
1
SbS
SbS
P2
P2
P1
P1
D
12
Aerial
Aerial
15
OGI
OGI
ECSbus
ECSbus
Stop
Stop
SbS
SbS
L4
L3
L2
L1
SbS
P4
P3
P2
P1
TX
RX
led
SAFE
English – 6