Radio Transmitters Memorisation - Nice MhouseKit WU200S Instructions Et Avertissements Pour L'installation Et L'utilisation

Kit complet pour automatiser un portail battant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For correct photocells recognition by the control unit, you need to carry
out its addressing, through the use of suitable electrical jumpers. The
addressing operation must be carried out both on TX and RX (setting the
electrical jumpers in the same way) and by making sure there are no other
couples of photocells with the same address. The photocells addressing
serves both for correct recognition by other devices on the ECSBus, and
to assign the function performed.
01. Open the photocell housing.
02. Locate the position in which they are installed according to Figure 39
and install the jumper according to Table 8.
The unused jumpers are stored in a compartment on their reserve, to
be able to be reused in the future(fig. 40).
03. Carry out the recognition phase as described in paragraph 10.3.3
"Recognition of other devices".
38
Photocell
A
Photocell h = 50cm activated
when gate closes
Photocell h = 100cm
B
activated when gate closes
Photocell h = 50cm activated
C
when gate opens and closes

9.4 - RADIO TRANSMITTERS MEMORISATION

The control unit contains a radio receiver for transmitters GTX4; the trans-
mitter contained in the package is already memorised and working.
If you want to memorise a new radio transmitter you have two possible
choices:
• M ode 1: in this "mode" the radio transmitter is used in full, that is, all
the keys carry out a predefined command (the transmitters supplied with
WU200S are memorised in Mode 1). It is clear that in mode 1 a radio
transmitter can be used to control a single automation; namely:
Key T1
"OPEN" command
Key T2
"Pedestrian Opening" command
Key T3
"Open Only" command
Key T4
"Close Only" command
24 – English
39
40
A
B
TABLE 8
Jumper
Photocell h = 100cm
D
activated when gate opens
and closes
Right photocell activated
E
when gate opens
Left photocell activated
F
when gate opens
• M ode 2: one of the four available commands can be assigned to each
key. By using this mode correctly, you can also control 2 or more different
automations; for example:
Key T1
Key T2
Key T3
Key T4
Naturally each transmitter is a specific case and in the same control unit
there may be some stored in mode 1 and others in mode 2.
Overall, the memory capacity is 150 units; mode 1 memorisation occu-
pies a unit for each transmitter while mode 2 occupies a unit for each key.
Caution! – Since the memorization procedures are timed (10s), you
must read the instructions in the following paragraphs before you
proceed with their execution.
Photocell
"Open Only" command Automation No. 1
"Close Only" command Automation No. 1
"OPEN" command Automation No. 2
"OPEN" command Automation No. 3
Jumper

Publicité

Table des Matières
loading

Table des Matières