KS100 key selector switch (optional)
Type
Technology adopted
Tamper-proof
Security lock
Power supply/contacts
Maximum cable length
Ambient operating temperature
Use in acid, saline or potentially
explosive atmospheres
Mounting
Protection rating
Dimensions / weight
FL100 signalling light (optional)
Type
Technology adopted
Lamp
Power input
Ambient operating temperature
Use in acid, saline or potentially
explosive atmospheres
Mounting
Protection rating
Dimensions / weight
GTX4 transmitters
Type
Technology adopted
Frequency
Coding
Buttons
Radiated power
Power input
Battery life
Ambient operating temperature
Use in acid, saline or potentially
explosive atmospheres
Protection rating
Dimensions / weight
Key-operated double switch suitable for control of automatic gates and doors. Illuminated for
night operation
Activation protected by a lock, the insertion and clockwise turning of the key causes the closing of
a contact, the anticlockwise turning of the key causes the closing of the second contact; spring-
loaded for return of key to the centre position
The selector switch can be opened only by inserting the key and turning it in either direction
Key with 450 different key numbers
The device can only be connected to the "OPEN" and "STOP" terminals on the control units
Mhouse, to which it sends the control signals and by which it is energized for night illumina-
tion
Up to 20 m (observe the warnings in the control units regarding minimum gauge and type of
cables)
-20 ÷ 50°
No
Vertical, wall-mounted
IP44
89 x 65 h 37mm / 120 g
Flashing indicator light for automatic gate and door automations
The device incorporates a receiving antenna for remote control
Illuminating indicator with 12V 21W lamp, controlled by the control units on Mhouse automa-
tion
12V 21W BA15 fitting (self-moving lamp type)
The device may only be connected to the "FLASH" and "ANTENNA" terminals on Mhouse auto-
mation control units.
-20 ÷ 50°C
No
Horizontal on the ground or vertical on the wall
IP55
120 x 60 h 170mm / 285g
Radio transmitters for remote control of automations for automatic gates and doors
AM OOK radio encoded modulation
433.92 MHz
Rolling code with 64 Bit code (18 billion, billion combinations)
4, each key can be used for the various control unit commands or to command other control units
0.001 W approx.
3V +20% -40% with 1 lithium battery type CR2032
3 years, estimated on the basis of 10 commands/day, each lasting 1s at 20°C (at low tempera-
tures the efficiency of the batteries decreases)
-20 ÷ 50°C
No
IP40 (suitable for use indoors or in protected environments)
50 x 50 h 17mm / 16g
English – 31