INSTALLATION HINTS

The DOSATRON can be connected
to the main water line directly
(Fig. 4) ; on a by-pass (Fig. 5),
recommended.
If your flow rate is above the
operating limits of the DOSATRON,
see EXCESSIVE FLOW.
To prolong the working life of the
DOSATRON it is advisable to install
a filter (ex.: 300 mesh - 60 microns
depending on your water quality)
upstream.
This is imperative if the water contains
impurities or particles, especially if
the water comes from a well.
A filter is recommended and
Valve
Filter
Fig. 4
EXCESSIVE FLOW (as an indication)
If your DOSATRON clicks more than 46 times in 15 seconds (meaning 23 cycles),
you are close to the maximum flow limit.
If you need more flow, you must install a DOSATRON with a superior capacity of
flow.
%
5
©
DOSATRON INTERNATIONAL S.A.S / 49
required for the warranty to be
valid.
Installing
the
a bypass enables clean water to
be supplied without operating the
DOSATRON and the DOSATRON to
be easily removed for maintenance.
When connecting an
installation to the public
water supply, you must
respect the rules and
regulations in force in the
country.
Valve
Filter
DOSATRON
on
Check
valve
%
5